TS2000 CTT Toroidal Conductivity Transmitter

Link Copied

10 Piece (MOQ)

Business Type Manufacturer, Exporter, Supplier
Product PDF View
Type Conductivity Transmitter
Material SS-316
Click to view more

Product Details

Features
SS-316 Enclosure With High Corrosion Resistance, IP-68 Protection, RS-485 Communication, 4–20 MA Analog Output, Backlit LCD Display, Supports Remote/Integral Sensor Connection
Input Type
Toroidal Conductivity Electrode
Output Type
4–20 MA DC Output
Communication Output
RS-485 MODBUS RTU
Display
Local Backlit LCD
Calibration Range
200 To 2,000,000 µS/cm
Maximum Measuring Span
2,000,000 µS/cm
Accuracy
±0.25% F.S.
Isolation
1.4 KV Between Input, Output & Power Supply
Electrical Connections
M12 Connector
Sensor Connection
Remote Or Integral
Power Supply
24V DC
Power Consumption
< 5W
Response Time
1 Second
Temperature Coefficient
±0.01% Per °C
Temperature Compensation
RTD PT-100
Electronics Enclosure
SS-316
Protection Class
Weatherproof IP-68
Mounting
2
Ambient Temperature
–20°C To +60°C
Ambient Humidity
5% To 95% (non-condensing)

TS2000 CT – Conductivity Transmitter Switch Features

  • SS-316 enclosure with high corrosion resistance

  • IP-68 protection for harsh industrial environments

  • RS-485 (MODBUS RTU) communication (optional)

  • 4–20 mA analog output

  • Backlit LCD display for clear visibility

  • Supports Remote / Integral sensor connection

  Technical Specifications Performance Characteristics

Type of Input

  • Toroidal Conductivity Electrode

Type of Output

  • 4–20 mA DC Output

Relay Output

  • 1 Relay (Optional)

Communication Output

  • RS-485 MODBUS RTU (Optional)

Display

  • Local backlit LCD

Calibration Range

  • 200 to 2,000,000 µS/cm

Maximum Measuring Span

  • 2,000,000 µS/cm

Accuracy

  • ±0.25% F.S.

Isolation

  • 1.4 kV between input, output & power supply

  Electrical & Connection

Electrical Connections

  • M12 Connector

Sensor Connection

  • Remote or Integral

Power Supply

  • 24V DC

Power Consumption

  • < 5W

Response Time

  • 1 Second

Temperature Coefficient

  • ±0.01% per °C

Temperature Compensation

  • RTD PT-100

Mechanical & Environmental

Electronics Enclosure

  • SS-316

Protection Class

  • Weatherproof IP-68

Mounting

  • 2" Pipe Mounting

Ambient Temperature

  • –20°C to +60°C

Ambient Humidity

  • 5% to 95% (non-condensing)

Flow-Through Assembly (Optional)

 

  • SS-316 / PP

Yes! I am interested