Display Backlight LCD - 6 Digit For Flow Rate, 8 Digit For Flow Totalizer
Accuracy +0.5% Of M.V.
Click to view more

Product Details

Usage
Conductive Liquids
Type
Electromagnetic Flow Meter Switch
Line Size Range
DN 15 To DN 300
Protection Class
IP68
Process Temperature
200°C Max
Process Pressure
16 Kg/cm Max
Output Signal
4 To 20mA,Pulse - Open Collector Type (Optional)
Communication Output
RS-485 MODBUS RTU (Optional)
Response Time
1Sec
Excitation
Pulsed DC
Media
Liquid (Conductive)
Conductivity
>5 PS/cm
Viscosity
200 Cp Max
Ambient Conditions
20°C To 40°C,5 To 95% Non-condensing

Features

  • Full-bore type electromagnetic flow meter

  • Potential-free relay output for ON/OFF control

  • Suitable for conductive liquids

  • Empty pipe detection

  • Available in line sizes DN 15 to DN 300

  • High measurement accuracy of ±0.5% of M.V.

  • Protection class: IP-68 (sensor + electronics)

  • Rugged SS-316 construction ensures long-term durability and corrosion resistance

  Technical Specifications Performance Characteristics

  • Measuring Principle: Electromagnetic flow measurement

  • Media: Conductive liquids

  • Conductivity: > 5 µS/cm

  • Viscosity: ≤ 200 cP

  • Line Size: 15 NB to 300 NB

  • Accuracy: ±0.5% of M.V.

  • Excitation: Pulsed DC

  • Response Time: 1 sec

  • Display: Backlit LCD

    • 6-digit flow rate

    • 8-digit totalizer

  Process Conditions

  • Process Temperature: up to 200°C

  • Process Pressure: up to 16 kg/cm²

  • Mounting Type: Inline – Horizontal / Vertical

  • Process Connection: ANSI 150 flanged as per Table B 16.5 (others on request)

Ambient Conditions

  • Ambient Temperature: –20°C to +75°C

  • Humidity: 5% to 95% RH (non-condensing)

  Output Signals

  • Output 1: 4–20 mA

  • Output 2: Pulse (Open Collector Type) – Optional

  • Alarm/Relay Output: 1 potential-free relay – Optional

  • Communication: RS-485 MODBUS RTU – Optional

  Protection

  • Electronics Protection: Weatherproof IP-68

  • Sensor / Flow Tube Protection: Weatherproof IP-68

  • Electronics Location: Integral or remote

  • Remote Cable Length: 5 meters

  • Electrical Connection: M12 connector

  Power Requirements

  • Voltage Supply: 18–30 V DC

  • Power Consumption: < 5 VA

  Material of Construction

 

  • Lining Options: Neoprene, Ebonite Rubber, PFA, PTFE, PU, Ceramic

  • Flange Material: MS, CS, SS-316, SS-304

  • Coil Housing: SS-316L

  • Electrodes: SS-316L / Hastelloy C / Platinum / Tantalum / Titanium

  • Electronics Enclosure: SS-316